User's Manual Part 2

December 20, 2004 SCP-LPS20x-011-012-01H
ADC Telecommunications, Inc. 95
SERVICE SENSOR PARAMETERS
Default Gateway
Select this option to poll the default gateway. If the gateway does not respond to the poll within 1 second, the radio is
turned off. This setting is not configurable. If Security filters are enabled, the default gateway must be the address
of the access controller.
Custom
Select this option to manually specify the IP address or domain name of the device to poll, the retry limit and timeout.
If you are using an ADC access controller, you can use the MAC authentication option to allow the LPS-20x to log
into the RADIUS server. This enables you to define an access list specifically for the LPS-20x that allows for access
to the required device.
Retry
Specify how many retries the LPS-20x will attempt when polling. When the retry limit is reached, the radio on the
LPS-20x is turned off. For example, if you set retry to 4, then the LPS-20x will make 5 attempts to poll the device at
the specified address. After the fifth failed poll, the radio will be turned off.
Timeout
Specify how long the LPS-20x will wait for a response to the poll before timing out.