INSTALLATION AND TEST
The LPS-20xR can be mounted to either a wall or pole.
To ensure the safety of personnel and equipment, observe the following safety rules:
FOR EQUIPMENT USING AN RFT CIRCUIT
At the time of installation, a system assessment must be carried out to ensure that the effective capacitance of the
total system, including the capacitance if the AP does not exceed 400
µf line to earth and 13 µf line to line.
At the time of installation, you must ensure that the voltage rating of the wiring of the AP is adequate for the normal
RFT circuit voltage along with superimposed transients and that the circuits to be connected together are either all
RFT-C circuits or all RFT-V circuits.
Required Tools
(2) #10 x 1-1/2” wood screws
(2) #10 x 1” anchors
(2) #10 flat washers
1/4-inch flat-head screwdriver
No. 1 Phillips screwdriver
216 Tool (can wrench) or 3/8” insulated nut driver
5/32-inch hex key, drilled for tamper-proof fasteners
insulated-handle wire stripper
insulated-handle needlenose pliers
insulated-handle wire cutter
PREPARING THE UNIT
DANGER
Always treat the xDSL pair as if it were live with high voltage present. Follow local practice when
installing a xDSL pair because voltages up to ±135 Vdc may be present.
All wiring external to this product should conform to local wiring codes and practices.
ATTENTION
STATIC SENSITIVE DEVICE – DO NOT HANDLE ANY MATERIAL WITHOUT FIRST TAKING
PROPER STATIC CONTROL PRECAUTIONS.
WARNING
Maintain a minimum distance of 20 cm when operating this device to avoid RF Exposure.
Step Action
1 The xDSL wiring is threaded through the left rubber grommet at the bottom of the unit.
2 Use a knife to slice a small cross or “x” between the four small round punchouts in the left rubber
grommet.