User's Manual Part 1
SCP-LPS20x-011-012-01H December 20, 2004
8 ADC Telecommunications, Inc.
SPECIFICATIONS
Table 6 lists the specifications for the LPS-20x.
Table 6. Specifications
Category Item Value
Operational RFT Circuit Voltage
± 135 Vdc
Effective Capacitance between the tip
and ring connection points of the xDSL
conductors of the Telecommunication
Network
Effective Capacitance between the tip or
ring connection and earth of the xDSL
conductor of the Telecommunication
Network
Power Power Mode(s) Span powered (local power in future)
Power Consumption <13 W total for AP
Power-on operating voltage range ± 100 to ± 135 Vdc (nominal)
Polarity Tolerant of Tip/Ring reversals between CO
power module and AP
Voltage Class (Span Powering) NEBS Class A2
xDSL Line Attenuation < 0.5 dB
Line Code TC-PAM
Protection AP Gas tube primary with secondary protection
Environmental Temperature -4° F to +149° F
-20° C to +65° C
Humidity 5% to 95% (non-condensing)
Altitude -200 ft. MSL to 13,000 ft. MSL;
-60 m MSL to 4,000 m MSL
Compliance NEBS
GR-63-CORE, Issue 2
GR-1089-CORE, Issue 3
SR-3580, Level 3
Safety
UL/cUL 60950-1
UL/cUL 60950-21
EN 60950-1:2001
EN 60950-21:2003
EMC EN 300/328-2, V1.1.1:July 2000
EN 301 489-1, V1.2.1:August 2000
EN 301 489-17 V1.1.1:September 2000
EN 300 386-2 V1.1.3:December 1997