ip.access Ltd Building 2020 Cambourne Business Park Cambridge CB3 6DW United Kingdom Installation Guide ip.access Customer Safety and Regulatory Information Author(s) Lance Davidson 26/10/2004 © ip.access Ltd COMPANY CONFIDENTIAL -1- CENG0133_C_Customer_Safety_and _Regulatory_Information.
The information contained in this document is commercially confidential and must not be disclosed to third parties without prior consent. © ip.access Ltd COMPANY CONFIDENTIAL -2- CENG0133_C_Customer_Safety_and _Regulatory_Information.
1 REVISION HISTORY Version A B C Change Summary First release BSC notes updated Product 165 Included, Cambourne address updated © ip.access Ltd COMPANY CONFIDENTIAL -3- ECN 0190 0243 TBA Date Sept 2004 Aug 2005 Dec 2005 Author LED LED LED CENG0133_C_Customer_Safety_and _Regulatory_Information.
Contents 1 2 REVISION HISTORY ....................................................................................3 INTRODUCTION ...........................................................................................5 2.1 Purpose and Scope .................................................................................5 2.2 Related Documents .................................................................................5 2.3 Terminology...............................................................
2 INTRODUCTION 2.1 Purpose and Scope This document provides the customer with safety and regulatory warnings, cautions and information for the IP Access range of products. Products covered are the model 108, 110, 139, 140, 165 and 178 range of nanoBTS’s, model 109 and 126 power supplies, model 129 4U circuit switched BSC. 2.2 Related Documents This document shall be referenced by the individual product’s user guides. 2.
3 Model 109 POWER SUPPLY 3.1 109 - Handbook - Warnings and Cautions This document is written in English, please request a copy in your local language if required. This product is only intended to power products approved by IP Access. Ensure that only IP Access products are connected to an Ethernet circuit enabled for 48V operation, this also applies to outlets remote from the unit For indoor use only, output cabling is SELV / LAN for indoor routing only. Do not cover casing or otherwise impede cooling.
3.2 109 - Handbook - FCC Text WARNING This is a class B product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Federal Communications Commission Note: This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC rules.
Safety Standards • EN60950 (CE marked) • UL60950 Listed (File number E231617) (USA and Canada) “Hereby, ip.access declares that this Ethernet Power Inserter is in compliance with the essential requirements and other relevant provisions of Directives 73/23/EEC and 89/336/EEC." The PSU109 is supplied by Poly-Products Industries, model number ILA1711112.
4 Model 126 Ethernet Switch and Power Inserter 4.1 126 - Handbook - Warnings and Cautions This document is written in English, please request a copy in your local language if required. This product is only intended to power products approved by IP Access. Ensure that only IP Access approved products are connected to an Ethernet circuit enabled for 48V operation, this also applies to outlets remote from the unit.
When rack mounting, ensure that the internal rack temperature does not exceed the rating of this product. Do not apply power to unit if there is any evidence of condensation. Do not open casing as mains voltages may be present within the unit. AC inlet cable must carry suitable local approval (e.g. UL marking for US and Canadian markets). 126 - Input Power Source Specification • Unit may be powered via AC or DC (not both). • 90 to 132 and 180 to 264VAC (auto-ranging) via an IEC C13 connector.
Federal Communications Commission Note: This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
• • • IEC 60950 UL60950 Listed (File number E230296) (USA and Canada) CB certificate (DK-7033) “Hereby, ip.access declares that this Ethernet Switch / Power Inserter is in compliance with the essential requirements and other relevant provisions of Directives 73/23/EEC and 89/336/EEC." A copy of regulatory compliance documentation may be obtained in writing from “IP access Ltd, Building 2020, Cambourne Business Park, Cambourne, Cambridge, CB3 6DW, UK”. © ip.
5 NANOBTS Products 5.1 NanoBTS - Handbook - Warnings and Cautions This system is designed to be operated indoors as a fixed system device and must be located either on or near the ceiling away from the user. It must be mounted in a manner to ensure that all users and bystanders are kept a minimum of 20cm away from the integral antennas at all times. Do not touch or move the antenna(s) while the unit is transmitting or receiving.
PSU’s supplied by ip.access must not be used for powering any other equipment (unless carried out in a manner having prior written approval from IP Access). TIB ports on the NanoBTS may only be connected with ip.access supplied cables with part numbers 139-040, 139-041, 139-042, 139-043 or 165-076. Fitting external antenna or antenna cabling to the BTS invalidates the type approval, CE marking and UL listing referred to herein (unless carried out in a manner having prior written approval from IP Access).
nanoBTS nanoBTS ~ PSU φ RJ45(48v) ~ RJ45 PSU θ Ethernet Switch BSC θ PSU located at the switch φ PSU located at nanoBTS When using the ip.access model 126A Ethernet Switch and Power Inserter, external PSU’s are not required, the NanoBTS is connected locally or via site cabling to the powered ports of the 126. nanoBTS (max qty 7) RJ45(48v) ~ RJ45(48V) Ethernet 126A Ethernet Switch and 48V Power Inserter © ip.
5.3.1 NanoBTS - Handbook - Installing the PSU at the Ethernet switch. If the 109 PSU is located at the patch panel /output port of the Ethernet switch, it is important that the 109 PSU is connected exactly as illustrated below (failure to do so may cause damage to the switch). Ensure that the 109 PSU is placed in a location that is ventilated and that the connection leads provide no safety hazard.
5.4 NanoBTS - Handbook – FCC Text Standards • FCC Rule 47 Parts 2, 15, 24 NOTE: Changes or modifications not expressly approved by the party responsible for compliance may void the user's authority to operate this equipment.
5.6 NanoBTS – Handbook - Regulatory Compliance Statement The nanoBTS conforms to the following regulatory standards. Type Approvals • GSM essential requirements under article 3.2 of the R&TTE directive ETSI EN 301 502. CE Marking (CE0168). • FCC - see above. • ICE – see above. EMC Standards • ETSI EN 301 489-1 and –8, ETSI EN 301 502. • FCC - see above. • ICE – see above. Environmental Standards • ETS 300 019.
6 Model 129 BSC (Base Station Controller) 6.1 BSC – Handbook – Warnings and Cautions This document is written in English, please request a copy in your local language if required. To be located in a restricted access location (accessible to maintenance personnel only). For indoor use only, Ethernet and E1/T1 cabling is LAN / SELV for indoor routing and termination only. Do not block ventilation holes or otherwise impede cooling. Refer to National Engineering Code (USA).
Do not apply power to unit if there is any evidence of condensation. Do not open casing as mains voltages may be present within the unit. Casing is to be operated with all covers (including slot covers) in place for safe operation and to ensure correct cooling airflow. AC inlet cables must carry suitable local approval (e.g. UL marking for US and Canadian markets).
• • • • The AC variant has three independent inlets for the purposes of power source migration and redundancy, at least two of these require power for operation, all three require power for normal redundant operation. -38 to -75V (-48V nominal) DC via two sets of screw terminals. 500W 10A rating. The installer must ensure that each DC supply connection is fused externally at 5A and provision is made for an external disconnection device. Plastic covers (supplied) are to be fitted over -48V BSC connections.
Federal Communications Commission Note: This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
• cTUVus – the BSC 4U chassis (including backplane, power supplies and cooling fan tray) is a TUV Rheinland Listed product for USA and Canadian markets. “Hereby, ip.access declares that model 129 4U CircuitBSC is in compliance with the essential requirements and other relevant provisions of Directives 1999/5/EC, 73/23/EEC and 89/336/EEC .