User Manual

Table Of Contents
Page 40 FlexWave microBTS Installation and Commissioning Guide
© 2009, ADC Telecommunications, Inc.
ADCP-77-086 • Issue 2 • 04/2009 • Chapter 5 - microBTS Initial Configuration
Note: When setting the RF output power levels as described in BSC Configuration Manager
(ADCP-75-317) paragraph 6.44 “Radio Carrier.” The maximum settings are: No less than level 4 for
900 MHz products and no less than level 5 for 1800 MHz products. Failure to observe this precaution
may result in over driving the microBTS power amplifier which may require power cycling the equip-
ment to reset the Power Amplifier.