FlexWave microBTS Installation and Commissioning Guide Page 35
© 2009, ADC Telecommunications, Inc.
ADCP-77-086 • Issue 2 • 04/2009 • Chapter 4 - Installation Procedures
Use the following procedure to install the DC power wiring:
1 Locate the DC power cable that is provided separately with the enclosure.
2 Route the power cable between the DC power port, located on the underside of the enclo-
sure and the DC power supply as shown in Figure 4-8. It may be necessary to install a new
junction box for the 5 amp breaker if an existing junction box is not available.
Note: All electrical work must comply with local codes and requirements. A locally licensed electri-
cal contractor is best qualified to perform this work. For additional information, consult with the ADC
Customer Service.
DANGER: Use extreme caution when working with DC power. Ensure all power is disconnected
before working on power circuits.