FlexWave microBTS Installation and Commissioning Guide Page 31
© 2009, ADC Telecommunications, Inc.
ADCP-77-086 • Issue 2 • 04/2009 • Chapter 4 - Installation Procedures
4.1.7 AC Power Wiring Installation
A 20-foot connectorized 3-wire cable (also available in lengths of 40, 60, or 100 feet) is
provided for the AC power connections. The connectorized end of the cable connects to the
AC power port located on the bottom of the enclosure. The stub end of the cable must be
routed to an external junction box (not provided) for permanent connection to the AC power
system wiring.
The AC power source must supply 120 or 240 VAC, 50 or 60 Hz, single-phase power through
a 15 amp circuit breaker. The AC power cable provides three wire leads for line, neutral, and
ground connections. The power cable is rated for indoor or outdoor use and must not be placed
within electrical conduit as this will impede the cooling of the cable during usage. The electri-
cal junction box and any conduit, wire, and fittings required must be provided by the installer.
Figure 4-4: Connecting Base Station Antenna Cable to Antenna Port
Note: It is recommended that an AC outlet be installed near the enclosure for powering tools and test
equipment. This outlet must include a GFCI device for protection.