Page 30 FlexWave microBTS Installation and Commissioning Guide
© 2009, ADC Telecommunications, Inc.
ADCP-77-086 • Issue 2 • 04/2009 • Chapter 4 - Installation Procedures
4.1.6 Base Station Antenna Cable Installation
A coaxial antenna cable must be routed from the base station antenna to the microBTS enclo-
sure. The cable must be terminated with an N-type male connector for connection to the
microBTS antenna port or the lightning protector (accessory).
Use the following procedure to install the antenna cable(s):
1 Remove the dust cap from the N-type female connector located on the underside of the
enclosure as shown in Figure 4-4.
2 If specified, connect a lightning protector (accessory) to the antenna port.
3 Route the coaxial antenna cable from the base station antenna to the underside of the
enclosure.
4 Cut the antenna cable to the required length and terminate with an N-type male connector.
5 Connect the antenna cable to the lightning protector or to the antenna port.
Figure 4-3: IP backhaul Cable Installation
Note: To comply with Maximum Permissible Exposure (MPE) requirements, the maximum compos-
ite output from the antenna cannot exceed 1640 watts EIRP and the antenna must be permanently
installed in a fixed location that provides at least 6 meters (20 feet) of separation from all persons.
RJ-45 BACKHAUL
CONNECTOR PORT
BACKHAUL
CABLE
BOTTOM VIEW
22639-A
CONNECTOR
NUT
RJ-45
PLUG