User Manual
Table Of Contents
- FlexWave microBTS 1 x 1 and 2 x 1 Installation and Commissioning Guide
- Chapter 1 - Introduction
- Chapter 2 - Unpacking and Inspection
- Chapter 3 - Mounting Procedures
- Chapter 4 - Installation Procedures
- 4.1 Installation Overview
- 4.1.1 Installation Hardware Provided with microBTS Enclosure
- 4.1.2 Tools and Materials Required
- 4.1.3 Ground Wire Installation
- 4.1.4 Network Listen Antenna Installation
- 4.1.5 IP Backhaul Cable Installation
- 4.1.6 Base Station Antenna Cable Installation
- 4.1.7 AC Power Wiring Installation
- 4.1.8 DC Power Wiring Installation
- 4.1.9 Touch-Up Painting
- 4.1.10 Shield Installation (option)
- 4.2 microBTS Replacement
- 4.1 Installation Overview
- Chapter 5 - microBTS Initial Configuration
FlexWave microBTS Installation and Commissioning Guide Page 23
© 2009, ADC Telecommunications, Inc.
ADCP-77-086 • Issue 2 • 04/2009 • Chapter 3 - Mounting Procedures
1 Hang the enclosure from the mounting bracket as shown in Figure 3-7. The shoulder
screw in the rear side of the enclosure fits into the notch at the top of the mounting bracket.
2 Insert a 5/16 x 1-1/4-inch hex bolt through the hole in the mounting tab located at the
bottom of the enclosure.
3 Place a 5/16-inch flat washer and 5/16-inch flat washer on the hex bolt.
4 Thread a 5/16-inch nut onto the hex bolt and tighten securely.
3.1.7.6 Strand-Mount Installation
An accessory kit is available for mounting the microBTS enclosure from an overhead wire or
strand. The strand-mount kit can accommodate wire cable that ranges in size from 0.25 to
0.625 inches in diameter. A minimum break strength of 4400 lbs. is recommended. Stainless
steel cable is preferred.
Figure 3-7: Secure Standard Mounting Bracket
5/16 x 1-1/4-INCH
HEX BOLT
5/16 INCH NUT
5/16 INCH
LOCK WASHER
5/16 INCH
FLAT WASHER
22632-A
MOUNTING TAB
SHOULDER
SCREW