User Manual
Table Of Contents
- FlexWave microBTS 1 x 1 and 2 x 1 Installation and Commissioning Guide
- Chapter 1 - Introduction
- Chapter 2 - Unpacking and Inspection
- Chapter 3 - Mounting Procedures
- Chapter 4 - Installation Procedures
- 4.1 Installation Overview
- 4.1.1 Installation Hardware Provided with microBTS Enclosure
- 4.1.2 Tools and Materials Required
- 4.1.3 Ground Wire Installation
- 4.1.4 Network Listen Antenna Installation
- 4.1.5 IP Backhaul Cable Installation
- 4.1.6 Base Station Antenna Cable Installation
- 4.1.7 AC Power Wiring Installation
- 4.1.8 DC Power Wiring Installation
- 4.1.9 Touch-Up Painting
- 4.1.10 Shield Installation (option)
- 4.2 microBTS Replacement
- 4.1 Installation Overview
- Chapter 5 - microBTS Initial Configuration
FlexWave microBTS Installation and Commissioning Guide Page 21
© 2009, ADC Telecommunications, Inc.
ADCP-77-086 • Issue 2 • 04/2009 • Chapter 3 - Mounting Procedures
4 Drill a 3/16-inch hole in the utility pole at each of the locations marked in step 3.
5 Locate the two 3/8 x 1-1/2-inch lag screws (provided with the enclosure) and place a 3/8
inch lock washer and 3/8-inch flat washer on each screw.
6 Secure the mounting bracket to the pole using the screws and washers prepared in step 5.
Tighten screws until bracket is securely attached to the plywood.
7 Hang the enclosure from the mounting bracket as shown in Section 5.4.
3.1.7.4 Metal Utility Pole Mounting
Stainless steel strapping is provided for securing the mounting bracket to a cylindrical object
(such as a metal utility pole) that cannot be pierced with a screw or bolt. A special tool
(Panduit BT1HT) is required to properly secure and tension the strapping. Use the following
procedure to install the mounting bracket on a metal utility pole:
1 Insert the two sections of stainless steel metal strapping (provided with the enclosure)
through the slots in the mounting bracket and place in position for mounting as shown in
Figure 3-6. The end with the V-notch should be at the top.
Note: Two sections of stainless steel metal strapping are provided with the enclosure. If addi-
tional strapping is required, use 5/8 inch wide 304 AISI stainless steel strapping with a
minimum tensile strength of 700 lbs force.