7 Hang the enclosure from the mounting bracket as described in Section 5.4.
3.1.7.2 Masonry Wall Mounting
When mounting the enclosure on a masonry surface, locate the mounting anchors as close as
possible to the center of any bricks or blocks, especially the upper anchors. Use the following
procedure to install the standard mounting bracket on a masonry wall:
1 Hold the enclosure mounting bracket in position for installation on the masonry wall as
shown in Figure 3-4. The end with the V-notch should be at the top.
2 Using a pencil, mark the location of the mounting bracket’s two mounting holes on the
wall.
3 Drill holes in the wall (at the locations marked in step 2) that are the correct diameter for
the type of anchors being used. The recommended hole size for the ADC-provided
concrete anchors is 5/8 inch .
4 Set the anchors in the wall.
Figure 3-4: Secure Standard Mounting Bracket To a Masonry Wall
20766-D
3/8 x 1-1/2-INCH
LAG SCREW (2)
3/8-INCH FLAT
WASHER (2)
3/4-INCH PLYWOOD
BACKER BOARD
(SECURE TO WALL STUDS)
3/8-INCH LOCK
WASHER (2)
MOUNTING
BRACKET
NOTE: THE MOUNTING BRACKET IS
SHOWN WITH A VERTICAL ORIENTATION.
THE MOUNTING BRACKET MAY ALSO
BE MOUNTED HORIZONTALLY IF REQUIRED.