User Manual
Table Of Contents
- FlexWave microBTS 1 x 1 and 2 x 1 Installation and Commissioning Guide
- Chapter 1 - Introduction
- Chapter 2 - Unpacking and Inspection
- Chapter 3 - Mounting Procedures
- Chapter 4 - Installation Procedures
- 4.1 Installation Overview
- 4.1.1 Installation Hardware Provided with microBTS Enclosure
- 4.1.2 Tools and Materials Required
- 4.1.3 Ground Wire Installation
- 4.1.4 Network Listen Antenna Installation
- 4.1.5 IP Backhaul Cable Installation
- 4.1.6 Base Station Antenna Cable Installation
- 4.1.7 AC Power Wiring Installation
- 4.1.8 DC Power Wiring Installation
- 4.1.9 Touch-Up Painting
- 4.1.10 Shield Installation (option)
- 4.2 microBTS Replacement
- 4.1 Installation Overview
- Chapter 5 - microBTS Initial Configuration
Page 18 FlexWave microBTS Installation and Commissioning Guide
© 2009, ADC Telecommunications, Inc.
ADCP-77-086 • Issue 2 • 04/2009 • Chapter 3 - Mounting Procedures
3.1.7.1 Wood-Framed Wall Mounting
When mounting the enclosure on a wood-framed wall, it is recommended that pressure-treated
plywood with a minimum thickness of 0.75-inch (19.0 cm) be used as a backer board. The
backer must be firmly secured to the interior framing of the wall. Use the following procedure
to install the standard mounting bracket on a wood-framed wall:
1 Mount the plywood backer (not-provided) on the wall and firmly secure it to the wall’s
interior studs.
2 Hold the enclosure mounting bracket in position for installation on the plywood backer as
shown in Figure 3-3. The end with the V-notch should be at the top.
3 Mark the location of the mounting bracket’s two mounting holes on the plywood backer.
4 Drill a 3/16inch hole in the backer board at each of the locations marked in step 3.
5 Locate the two 3/8 x 1-1/2-inch lag screws (provided with the enclosure) and place a 3/8
inch lock washer and 3/8 inch flat washer on each screw.
6 Secure the mounting bracket to the plywood using the screws and washers prepared in step
5. Tighten screws until bracket is securely attached to the plywood.
Figure 3-3: Secure Standard Mounting Bracket To Plywood Backer
20766-D
3/8 x 1-1/2-INCH
LAG SCREW (2)
3/8-INCH FLAT
WASHER (2)
3/4-INCH PLYWOOD
BACKER BOARD
(SECURE TO WALL STUDS)
3/8-INCH LOCK
WASHER (2)
MOUNTING
BRACKET
NOTE: THE MOUNTING BRACKET IS
SHOWN WITH A VERTICAL ORIENTATION.
THE MOUNTING BRACKET MAY ALSO
BE MOUNTED HORIZONTALLY IF REQUIRED.