3.1.4 microBTS Dimensions
The basic dimensions of the microBTS are shown in Figure 3-1.
3/8 inch concrete anchors 4
3/8 x 1 inch cap screws 4
3/8 x 1.5 inch lag screws 4
3/8 x 1.5 inch flat washers 4
3/8 x 1.5 inch lock washers 4
5/16 x 1.25 inch cap screws 1
5/16 inch flat washer 1
5/16 inch lock washer 1
5/16 inch nut 1
Figure 3-1: microBTS Dimensions
Table 3-1: microBTS Mounting Hardware and Fasteners
Item Quantity
22636-A
9.7 IN.
(24.6 CM)
5.7 IN.
(14.5 CM)
29.4 IN.
(74.7 CM)