1.2.11 Specifications
The specifications for the microBTS are listed in Table 1-2.
E
3 Antenna symbol
N-type female RF
coaxial connector
Connection point for the base station antenna.
4Network symbol
Sealed RJ-45 female
connector
Connection point for the IP back haul cable
5 No designation Red LED (off/red)
Indicates if the microBTS is powered and normal (off)
or if a major fault is detected (red).
6
120/240 VAC 47-63 Hz
6.8 amps
Sealed 3-wire AC
power connector
Connection point for the AC power cord.
Table 1-2: microBTS Specifications
Parameter Specification Remarks
Physical/ Environmental/ Electrical
Enclosure dimensions (L x W x D)
29.4 x 9.7 x 5.7 inches (747 x 246 x 145
mm)
0.94 cu. ft. (26.6L)
Mounting Wall, pole, or strand
Strand mounting requires an
accessory mounting kit.
Weight 40 lbs (18.2 kg) Without shields installed
Weather resistance (see note 1) NEMA-6, IEC IP67 Indoor or outdoor installation
Operating temperature -30° to +55° C (-22° to +131° F)
Storage temperature -40° to +70° C (-40° to +158° F)
AC/DC power connector Sealed 3-pin AC/DC power
Antenna cable connector 50 Ohm N-type (female) 50 Ohms input/ output impedance
IP back haul connector Sealed RJ-45 (female) Ethernet port
Power over Ethernet port 48 VDC with 15 watt maximum
Network Listen antenna NMO (female)
Lightning suppression (for antenna
cable connector)
20 kA IEC 1000-4-5 8/20 µs waveform
Provided by external lightning
protector (accessory)
Voltage input 90 to 265 VAC, 47-63 Hz
Power consumption maximum 600 VA at 120 VAC
Table 1-1: microBTS User Interface
Ref
No
User Interface
Designation
Device Functional Description