User Manual
Table Of Contents
- FlexWave microBTS 1 x 1 and 2 x 1 Installation and Commissioning Guide
- Chapter 1 - Introduction
- Chapter 2 - Unpacking and Inspection
- Chapter 3 - Mounting Procedures
- Chapter 4 - Installation Procedures
- 4.1 Installation Overview
- 4.1.1 Installation Hardware Provided with microBTS Enclosure
- 4.1.2 Tools and Materials Required
- 4.1.3 Ground Wire Installation
- 4.1.4 Network Listen Antenna Installation
- 4.1.5 IP Backhaul Cable Installation
- 4.1.6 Base Station Antenna Cable Installation
- 4.1.7 AC Power Wiring Installation
- 4.1.8 DC Power Wiring Installation
- 4.1.9 Touch-Up Painting
- 4.1.10 Shield Installation (option)
- 4.2 microBTS Replacement
- 4.1 Installation Overview
- Chapter 5 - microBTS Initial Configuration
FlexWave microBTS Installation and Commissioning Guide Page 5
© 2009, ADC Telecommunications, Inc.
ADCP-77-086 • Issue 2 • 04/2009 • Chapter 1 - Introduction
wire terminated with a ring terminal is provided with the microBTS for linking the enclosure
to an earth ground source.
1.2.9 Cooling
Passive cooling of the electronic assemblies is provided by conducting excess heat from the
internal electronic components to the aluminum enclosure. The heat is then dissipated to the
outside air by radiation and convection air flow over the enclosure’s external cooling fins. An
alarm is generated if a high temperature condition occurs within the enclosure.
1.2.10 User Interface
The microBTS user interface consists of the connectors, grounding lug, and LED that are
provided on the exterior of the enclosure. The microBTS user interface points are indicated in
Figure 1-2 and described in Table 1-1.
E
Figure 1-2: microBTS User Interface
Table 1-1: microBTS User Interface
Ref
No
User Interface
Designation
Device Functional Description
1 No designation
NMO female RF
connector
Connection point for the Network Listen antenna.
2 Ground symbol
Threaded hole with
hex socket screw
Connection point for grounding wire.
22589-A
(5) LED
INDICATOR
TOP VIEW BOTTOM VIEW
(1) NETWORK LISTEN
ANTENNA CONNECTOR
(4) IP BACKHAUL
CABLE CONNECTOR
(2) GROUNDING WIRE
CONNECTION POINT
(6) AC POWER
CONNECTOR
NOTE: SHOWN WITH DUST CAPS REMOVED
(3) BASE STATION
ANTENNA
CONNECTOR