User's Manual Part 1

Table Of Contents
System Specifications
2-10 InterReach Fusion Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620610-0-20 Rev A
Table 2-2
Wavelength and Laser Power Specifications
Measured Output Power
Wavelength Main Hub Expansion Hub
1310 nm +20 nm 890 uW 3.8 mW
Table 2-3
Environmental Specifications
Parameter Main Hub and Expansion Hub RAU
Operating Temperature 0° to +45°C (+32° to +113°F) –25° to +45°C (–13°
to +113°F)
Non-operating Tempera-
ture
–20° to +85°C (–4° to +185°F) –25° to +85°C (–13°
to +185°F)
Operating Humidity;
non-condensing
5% to 95% 5% to 95%
Table 2-4
Frequency Bands Covered by Fusion RAUs
Fusion
RAU Part Number
Fusion
Band
RF Passband
Downlink
(MHz)
Uplink
(MHz)
MAIN
HUB/
RAU
Band
RAU
Band-
width
850/1900 FSN-8519-1 850 869–894 824–849 1 25 MHz
1900 1930–1990 1850–1910 2 60 MHz
900//1800 FSN-9018-1 900 925–960 880–915 1 35 MHz
1800 1805–1880 1710–1785 2 75 MHz
900/2100 FSN-9021-1 900 925–960 830–715 1 35 MHz
2100 2110–2170 1920–1980 2 60 MHz
800/900/
1900
FSN-809019-1 800
SMR
851-869 806-824 1 (sub
band
1A)
18 MHz
900
SMR
935-941 896-902 3 (sub
band
1B)
6 MHz
1900
(A-G)
1930-1995 1850-1915 2 65 MHz