Upon power up, the Hub goes through a 20-second test to check the LED lamps. Dur-
ing this time, the LEDs blink through the states shown in Table 3-1, letting you visu-
ally verify that the LED lamps and the firmware are functioning properly. Upon
completion of initialization, the LEDs stay in one of the first two states shown in
Table 3-1.
The Hub automatically sends the program bands command to all connected RAUs. A
mismatched band causes a fault message to be displayed in AdminBrowser and
places the RAU has a disabled condition.
NOTE: Refer to Section 9.3.2 for troubleshooting using the LEDs.
NOTE: AdminBrowser should be used for troubleshooting the system.
Only use LEDs for backup or confirmation. However, if there are communi-
cation problems within the system, the LEDs may provide additional infor-
mation that is not available using AdminBrowser.
Unit Status LEDs
The Hub has one pair of status LEDs, labeled POWER and STATUS, which can be in
one of the states shown in Table 3-1. These LEDs can be:
steady green
steady red
off - no color (valid only during 90 second power cycle)
There is no off state when the unit’s power is on.
Table 3-1 Fusion Hub Status LED States
LED State Indicates
Green
Green
The Main Hub is connected to power and all power supplies are operating.
The Main Hub is not reporting a fault; however, the system test may need to
be performed or a warning condition may exist. Use AdminBrowser to deter-
mine this.
Green
Red
The Main Hub is connected to power and all power supplies are operating.
Use AdminBrowser to power status.
The Main Hub is reporting a fault or lockout condition.