Instruction Manual
Table Of Contents
- SECTION 1 General Information
- SECTION 2 InterReach Fusion System Description
- SECTION 3 Fusion Main Hub
- SECTION 4 Fusion Expansion Hub
- SECTION 5 Remote Access Unit
- SECTION 6 Designing a Fusion Solution
- SECTION 7 Installing Fusion
- SECTION 8 Replacing Fusion Components
- SECTION 9 Maintenance, Troubleshooting, and Technical Assistance
- APPENDIX A Cables and Connectors
- A.1 75 Ohm CATV Cable
- A.2 Fiber Optical Cables
- A.3 Coaxial Cable
- A.4 Standard Modem Cable
- A.5 TCP/IP Cross-over Cable
- A.6 DB-25 to DB-9 Null Modem Cable
- APPENDIX B Compliance
- B.1 Fusion System Approval Status
- B.2 Human Exposure to RF
- APPENDIX C Faults, Warnings, Status Tables
- C.1 Fault Messages Reported by Hubs
- C.2 Faults Reported for System CPU
- C.3 Faults for RAUs
- C.4 Warning/Status Messages for Hubs
- C.5 Warning/Status Messages for System CPUs
- C.6 Warning /Status Messages for RAUs
Help Hot Line (U.S. only): 1-800-530-9960 2-7
D-620TBD-0-20 Rev A CONFIDENTIAL
System Connectivity
2.4 System Connectivity
The double star architecture of the Fusion system, illustrated in Figure 2-4, provides
excellent system scalability and reliability. The system requires only one pair of
fibers for eight antenna points. This makes any system expansion, such as adding an
extra antenna for additional coverage, potentially as easy as pulling an extra CATV
cable.
Figure 2-4 Fusion’s Double Star Architecture
Main Hub
RS-232
PORT 1 PORT 2 PORT 3 PORT 4
Expansion Hub
Expansion Hub
Fiber
Expansion Hub
Expansion Hub
CATVCATV (RG-39, 6, or 11) CATV
up to 8 RAUs per Expansion Hub
RAU RAU RAU