Instruction Manual
Table Of Contents
- SECTION 1 General Information
- SECTION 2 InterReach Fusion System Description
- SECTION 3 Fusion Main Hub
- SECTION 4 Fusion Expansion Hub
- SECTION 5 Remote Access Unit
- SECTION 6 Designing a Fusion Solution
- SECTION 7 Installing Fusion
- SECTION 8 Replacing Fusion Components
- SECTION 9 Maintenance, Troubleshooting, and Technical Assistance
- APPENDIX A Cables and Connectors
- A.1 75 Ohm CATV Cable
- A.2 Fiber Optical Cables
- A.3 Coaxial Cable
- A.4 Standard Modem Cable
- A.5 TCP/IP Cross-over Cable
- A.6 DB-25 to DB-9 Null Modem Cable
- APPENDIX B Compliance
- B.1 Fusion System Approval Status
- B.2 Human Exposure to RF
- APPENDIX C Faults, Warnings, Status Tables
- C.1 Fault Messages Reported by Hubs
- C.2 Faults Reported for System CPU
- C.3 Faults for RAUs
- C.4 Warning/Status Messages for Hubs
- C.5 Warning/Status Messages for System CPUs
- C.6 Warning /Status Messages for RAUs
C-10 InterReach Fusion Installation, Operation, and Referencer Manual
CONFIDENTIAL D-620TBD-0-20 Rev A
[M66]/S Problem detected in the Hub. Contact LGC Wireless Support for more information.
[M67]/S Problem detected in the Hub. Contact LGC Wireless Support for more information.
[M68]/S No UL test tone (Port 4/Band 1). Hub/Port UL path gain is low.
[M69]/S No UL test tone (Band 2). Hub/Port UL path gain is low.
[M70]/S No UL test tone (Port 2/Band 2). Hub/Port UL path gain is low.
[M71]/S No UL test tone (Port 3/Band 2). Hub/Port UL path gain is low.
[M72]/S No UL test tone (Port 4/Band 2). Hub/Port UL path gain is low.
[M73]/S No UL test tone (Band 3). Hub/Port UL path gain is low.
[M74]/S No UL test tone (Port 2/Band 3). Hub/Port UL path gain is low.
[M75]/S No UL test tone (Port 3/Band 3). Hub/Port UL path gain is low.
[M76]/S No UL test tone (Port 4/Band 3). Hub/Port UL path gain is low.
[M77]/S Problem detected in the Hub. Contact LGC Wireless Support for more information.
[M78]/S Problem detected in the Hub. Contact LGC Wireless Support for more information.
[M79]/S Problem detected in the Hub. Contact LGC Wireless Support for more information.
[M80]/S Problem detected in the Hub. Contact LGC Wireless Support for more information.
[M81]/W Port 1 DL path loss is high. If the problem is on more than one port, replace the Hub.
Switch the cable connection to a different hub port until the
Hub can be replaced.
[M82]/W Port 2 DL path loss is high. If the problem is on more than one port, replace the Hub.
Switch the cable connection to a different hub port until the
Hub can be replaced.
[M83]/W Port 3 DL path loss is high. If the problem is on more than one port, replace the Hub.
Switch the cable connection to a different hub port until the
Hub can be replaced.
[M84]/W Port 4 DL path loss is high. If the problem is on more than one port, replace the Hub.
Switch the cable connection to a different hub port until the
Hub can be replaced.
[M85]/W Port 5 DL path loss is high. If the problem is on more than one port, replace the Hub.
Switch the cable connection to a different hub port until the
Hub can be replaced.
[M86]/W Port 6 DL path loss is high. If the problem is on more than one port, replace the Hub.
Switch the cable connection to a different hub port until the
Hub can be replaced.
[M87]/W Port 7 DL path loss is high. If the problem is on more than one port, replace the Hub.
Switch the cable connection to a different hub port until the
Hub can be replaced.
[M88]/W Port 8 DL path loss is high. If the problem is on more than one port, replace the Hub.
Switch the cable connection to a different hub port until the
Hub can be replaced.
[M89]/W Port 1 UL path loss is high. Check the cable for high RF loss. Switch the cable connec-
tion to a different hub port. If the problem on more than one
port, replace the Hub, otherwise replace the RAU.
[M90]/W Port 2 UL path loss is high. Check the cable for high RF loss. Switch the cable connec-
tion to a different hub port. If the problem is on more than
one port, replace the Hub, otherwise replace the RAU.
[M91]/W Port 3 UL path loss is high. Check the cable for high RF loss. Switch the cable connec-
tion to a different hub port. If the problem is on more than
one port, replace the Hub, otherwise replace the RAU.
Table C-4 Warnings/Status Messages for Hubs (continued)
Message
Number/
Default Description Reason/Action