[Mnn]/X where nn equals the message number, and X equals the default of either Sta-
tus (S) or Warning (W).
Table C-4 Warnings/Status Messages for Hubs
Message
Number/
Default Description Reason/Action
[M01]/S Fan 1 failure. Check the fan for rotation, air flow blockage, and dust.
Replace the Hub on high temperature warning.
[M02]/S Fan 2 failure. Check the fan for rotation, air flow blockage, and dust.
Replace the Hub on high temperature warning.
[M03]/S 54 VDC Pwr Supply Fan failure. Check the fan for rotation, air flow blockage, and dust.
Replace the Hub on high temperature warning.
[M04]/W 5 VDC Monitor. DC power out of range, replace the Hub.
[M05]/W 9 VDC Monitor. DC power out of range, replace the Hub.
[M06]/W 54 VDC Monitor. DC power out of range, replace the Hub.
[M07]/W 3 VDC Monitor. DC power out of range, replace the Hub.
[M08]/W 12 VDC Monitor. DC power out of range, replace the Hub.
[M09]/W Temperature High. Reduce ambient temperature, check for air flow blockage,
fan rotation.
[M10]/S Problem detected in the Hub. Contact LGC Wireless Support for more information.
[M11]/S Problem detected in the Hub. Contact LGC Wireless Support for more information.
[M12]/S Problem detected in the Hub. Contact LGC Wireless Support for more information.
[M13]/S Problem detected in the Hub. Contact LGC Wireless Support for more information.
[M14]/S Problem detected in the Hub. Contact LGC Wireless Support for more information.
[M15]/S Problem detected in the Hub. Contact LGC Wireless Support for more information.
[M16]/S Problem detected in the Hub. Contact LGC Wireless Support for more information.
[M17]/S Hardware failure (Test Tone PLL
Band 1).
Unable to perform DL system test.
[M18]/S Hardware failure (Test Tone Too
High Band 1).
Unable to perform DL system test.
[M19]/S Hardware failure (Test Tone Too
Low Band 1).
Unable to perform DL system test.
[M20]/W Overdrive limiter active (Band 1). Reduce input signal power to avoid potential component
damage.
[M21]/W CEMark limiter at maximum
(Band 1).
Reduce input signal power to avoid drop in system gain.
[M22]/S Problem detected in the system. Contact LGC Wireless Support for more information.
[M23]/S Problem detected in the system. Contact LGC Wireless Support for more information.
[M24]/S Problem detected in the system. Contact LGC Wireless Support for more information.
[M25]/S Hardware failure (Test Tone PLL
Band 2).
Unable to perform DL system test. Replace the hub when
possible.
[M26]/S Hardware failure (Test Tone Too
High Band 2).
Unable to perform DL system test. Replace the hub when
possible.
[M27]/S Hardware failure (Test Tone Too
Low Band 2).
Unable to perform DL system test. Replace the hub when
possible.
[M28]/W Overdrive limiter active (Band 2). Reduce input signal power to avoid potential component
damage.
[M29]/W CEMark limiter at maximum
(Band 2).
Reduce input signal power to avoid drop in system gain.