Fusion Installation Procedures
7-24 InterReach Fusion Installation, Operation, and Reference Manual
CONFIDENTIAL D-620TBD-0-20 Rev A
2. Expansion
Hub power
is On and
RAUs are
connected
PORT
Off Check the CATV cable. Power is not getting to the
RAU.
PORT
Flashing Red
(60 PPM)
Test the CATV cable. If the cable
tests OK, try another port. If the
second port’s LEDs are Red/Off,
replace the RAU. If the second
RAU doesn’t work; replace the
Expansion Hub.
Power levels to RAU are not
correct; communications are
not established.
If the second port works, flag
the first port as unusable;
replace EH when possible.
PORT
Red Use AdminBrowser to determine
the problem.
RAU is off-line.
Table 7-6 Troubleshooting Expansion Hub LEDs During Installation
During
Installation LED State Action Impact