Figure 7-1 Mounting Bracket Detail
Installing an Optional Cable Manager in the Rack
Using the screws provided, fasten the cable manager to the rack, immediately
above or below the Main Hub.
Installing a Main Hub Using the 12” Wall-Mounted Rack (PN 4712)
Considerations:
The rack-mounting brackets on the Fusion Main Hub must be moved to the
recessed mounting position to allow for the required 76 mm (3 in.) rear clearance.
• The maximum weight the bracket can hold is 22.5 kg (50 lbs).
• The bracket is designed to accommodate a Fusion Main Hub (12 lbs.) or an
Expansion Hub (14.5 lbs.).
The wall mount bracket should be securely mounted to wall, using the four key slot
mounting holes on the bracket.
To install the Hub directly to the wall:
1. Attach the wall bracket (PN 4712) to wall the using #10 Pan Head wood screws,
1-1/2” minimum length for mounting in wood studs or 3/4“thick plywood.
The bracket must be positioned so that the Hub will be in a horizontal position
when it is installed. (Refer to Figure 7-2.)