SYSTEM GAIN
The system gain of the Fusion Wideband defaults to 0 dB or can be set up to 15 dB in 1 dB
increments. In addition, uplink and downlink gains of each RAU can be independently attenuated
by 0 or 10 dB using AdminBrowser.
The recommended maximum lengths of CATV cable are as follows:
For RG-59
cable 130 meters for CommScope PN 2065V
For RG-6 c
able 140 meters for CommScope PN 2279V
For RG-11
cable 235 meters for CommScope PN 2293K.
If the maximum distance is not required, then copper-clad over steel c
enter-conductor cable may
be use to reduce cable costs.
If the CATV cable is longer than the recommended distance per cab
le type, the gain of the system
will decrease, as shown in Table 69.
Table 69.
System Gain (Loss) Relative to CATV Cable Length
Cable
Type
Comm-Sc
ope Part
Number
Plenum
Rated
Solid Copper
Conductor
Copper Clad
Conductor
Zero-loss RF
Maximum
Length
(meters)
Distance
Where RF
is 10dB
Below Input
RF
(meters)
RG-59 2065V Yes X 130 180
2022V Yes X 100 100*
5572R No X 95 95*
5565 No X 130 180
RG-6 2279V Yes X 140 190
2275V Yes X 140 150*
5726 No X 140 140*
5765 No X 140 190
RG-11 2293K Yes X 235 320
2285K Yes X 235 300*
5913 No X 235 300*
* Exceeding the distance of copper-clad
cable will result in
the connected RAU becoming
non-functional. If the distance of a cable run is at its maximum and is of concern, use solid copper
cable to ensure successful operation.