Page 48 InterReach Fusion Wideband Installation, Operation, and Reference Manual
© 2015 TE Connectivity D-620616-0-20 Rev K TECP-77-044 Issue 9 March 2015
EXPANSION HUB REAR PANEL
Figure 12. Expansion Hub Rear Panel
Ref # Description
1 AC power cord connector
2 Two air exhaust vents
3 One 9-pin D-sub female connector labeled ALARMS for contact alarm monitoring; for pinouts, see Table 37. This
interface can monitor three single external alarm contacts (Alarm Sense Input 1). This interface monitors the output
contact closures from a Universal Power Supply (UPS). Verify the output contact closure state (normally closed or
normally open) of the UPS, and set the appropriate contact definition using AdminBrowser.
Faults are service impacting.
W
arnings indicate a possible service impact.
Status messages are generally not service impacting.
4 Ground lug labeled GROUND for connecting
unit to frame ground
Table 37. 9-Pin D-Sub Pin Connector Functions
Pin Function
1 Alarm Sense Input (DC Ground)
2 Alarm Sense Input 3
3 Alarm Sense Input 2
4 N/C
5 N/C
6 DC Ground (common)
7 N/C
8 Alarm Sense Input 1
9 N/C
AC POWER
ALARMS
GND
1234