User's Manual

Table Of Contents
System Specifications
InterReach Fusion Wideband Installation, Operation, and Reference Manual Page 15
D-620616-0-20 Rev K TECP-77-044 Issue 9 March 2015 © 2015 TE Connectivity
SYSTEM SPECIFICATIONS
NOTE: Note: The Fusion Wideband Main Hub’s typical power consumption assumes that the CATV
RG-59 cable length is no more than 130 meters, the RG-6 cable length is no more than 140
meters, and RG-11 cable length is no more than 235 meters using CommScope 2065V, 2279V, and
2293K cables.
Table 1. Physical Specifications
Parameter Main Hub Expansion Hub Remote Access Unit
IF/RF Connectors 4-type “N” female
(a)
(50 Ohm),
1 Downlink/Uplink pair per
ban
d
8-type “F”, female
(CATV 75 Ohm)
One F, female (CATV -75 Ohm)
One N, female
(b)
(antenna-50 Ohm)
External Alarm Connector
(contact source)
One, 9-pin D-sub, female One, 9-pin D-sub, female
ADMIN/LAN Interface
Connectors
One RJ-45, female
One 9-pin D-sub, male for
optional modem
One RJ-45, female
One 9-pin D-sub, male
Fiber Connectors
(c)
4 pair, SC/APC
(d)
One pair, SC/APC
LED Alarm and Status
Indicators
Unit Status (One pair):
•Power
M
ain Hub Status
Downstream Unit Status
(One per fiber port):
Expansion Hub/RAU
Unit Status (One pair):
•Power
Expansion Hub Status
Fiber Link Status (One pair):
•DL Status
•U
L
Status
Port Status:
One per F connector port
•L
i
nk/RAU
Unit Status (One pair):
•Link
•Al
arm
Power (AC Option) Rating: 100–240V AC, 1A,
5
0–60
Hz
Operating Range: 90–132V
AC/170-250V
AC auto-
ranging
Rating: 100–240V AC, 6A,
50
–60
Hz
Operating Range: 90–132V
AC/170-250V AC
auto-
ranging
Power (DC Option) Rating: 38–64V DC, 2.5A Rating: 38-64V DC, 14A
Power Consumption (W) 30 4 RAUs: 290 typical, 360 max.
8 RAUs: 500 typical, 630 Max.
Enclosure Dimensions
(e)
(height ´ width ´ depth)
89 mm × 438 mm × 381 mm
(3.5 in. × 17.25 in. × 15 in.)
2U
89 mm × 438 mm × 381 mm
(3.5 in. × 17.25 in. × 15 in.)
2U
54 mm x 286 mm x 281 mm
(2.13 in. × 11.25 in. × 11.13 in.)
Weight < 5.5 kg (< 12 lbs.) < 6.6 kg (< 14.5 lbs.) < 2.1 kg (< 4.6 lbs.)
a 6-type N, female connectors for FSN-W2-MH-1, FSN-W2-MH-3, FSN-W4-MH-1, and FSN-W5-MH-1 Main Hub.
b 2-type N, female connectors for FSN-W1-1921-1, FSN-W2-80851
9-1, FSN-W2-7575-1, FSN-W2-7070-1, FSN-W3-2626-1,
FSN-W4-702121-1-HP, FSN-W4-752121-1-HP, FSN-W5-851921-1-HP, and FSN-2525-1-TDD RAUs.
c It is critical to system performance that
only
SC/APC fiber connectors are used throughout the fiber network, including fiber distribution
panels.
d FSN-W1-MH-2-1P, FSN-W1-MH-3-1P, FSN-W2-MH-3-1P, FSN-W3-MH-1P,
FSN-W4-MH-1P, and FSN-W5-MH-1P support only one pair,
SP/APC fibers.
e Excluding angle-brackets for
19'' rack hub mounting of the hub.