User's Manual

Table Of Contents
Messages for Main Hubs
InterReach Fusion Wideband Installation, Operation, and Reference Manual Page 221
D-620616-0-20 Rev K TECP-77-044 Issue 9 March 2015 © 2015 TE Connectivity
[M94]/W Port 6 UL path loss is high. Check the cable for high RF loss. Switch the cable connection to a
different hub port. If the problem is on more than one port, replace
the Hub, otherwise replace the RAU.
[M95]/W Port 7 UL path loss is high. Check the cable for high RF loss. Switch th
e cable connection
to a
different hub port. If the problem is on more than one port, replace
the Hub, otherwise replace the RAU.
[M96]/W Port 8 UL path loss is high. Check the cable for high RF loss. Switch th
e cable connection
to a
different hub port. If the problem is on more than one port, replace
the Hub, otherwise replace the RAU.
[M97]/W Port 1 UL path exceeds maximum gain. If the problem is common to more than one port, replace the Hub,
othe
rwise check the RAU.
[M98]/W Port 2 UL path exceeds maximum gain. If the problem is common to more than one port, replace the Hub,
ot
he
rwise check the RAU.
[M99]/W Port 2 UL path exceeds maximum gain. If the problem is common to more than one port, replace the Hub,
othe
rwise check the RAU.
[M100]/W Port 2 UL path exceeds maximum gain. If the problem is common to more than one port, replace the Hub,
othe
rwise check the RAU.
[M101]/W Port 2 UL path exceeds maximum gain. If the problem is common to more than one port, replace the Hub,
ot
he
rwise check the RAU.
[M102]/W Port 2 UL path exceeds maximum gain. If the problem is common to more than one port, replace the Hub,
othe
rwise check the RAU.
[M103]/W Port 2 UL path exceeds maximum gain. If the problem is common to more than one port, replace the Hub,
othe
rwise check the RAU.
[M104]/W Port 8 UL path exceeds maximum gain. If the problem is common to more than one port, replace the Hub,
ot
he
rwise check the RAU.
[M105]/W Port 1 54 VDC Power Enabled. Caution: Port 54 VDC power may be present at the output.
[M106]/W Port 2 54 VDC Power Enabled. Caution: Port 54 VDC power may be present at the output.
[M107]/W Port 3 54 VDC Power Enabled. Caution: Port 54 VDC power may be present at the output.
[M108]/W Port 4 54 VDC Power Enabled. Caution: Port 54 VDC power may be present at the output.
[M109]/W Port 5 54 VDC Power Enabled. Caution: Port 54 VDC power may be present at the output.
[M110]/W Port 6 54 VDC Power Enabled. Caution: Port 54 VDC power may be present at the output.
[M111]/W Port 7 54 VDC Power Enabled. Caution: Port 54 VDC power may be present at the output.
[M112]/W Port 8 54 VDC Power Enabled. Caution: Port 54 VDC power may be present at the output.
Table 107. Warnings/Status Messages for Main Hubs (Cont.)
Message
Number/
Default
Description Reason/Action