User's Manual

Table Of Contents
Appendix C: Faults, Warnings, Status Tables for Fusion, Fusion Wideband, Fusion SingleStar
Page 216 InterReach Fusion Wideband Installation, Operation, and Reference Manual
© 2015 TE Connectivity D-620616-0-20 Rev K TECP-77-044 Issue 9 March 2015
FAULTS FOR RAUS
Table 106. Faults for RAUs
Message
Number
Description Reason/Action
{RF01} Software error occurred and recovered. If this happens repeatedly, replace the RAU.
{RF02} Software error occurred and recovered. If this happens repeatedly, r
eplace the RAU.
{RF03} Software error occurred and recovered. If this happens repeatedly, r
eplace the RAU.
{RF04} Software reset occurred and recovered,
or firmware
download.
If this happens repeatedly, replace the RAU.
{RF05} Software error occurred and recovered. If this happens repeatedly, r
eplace the RAU.
{RF06} Problem detected in the RAU. Contact TE Support for more information.
{RF07} RAU power cycle. RAU power cycle.
{RF08} Problem detected in the RAU. Contact TE Support for more information.
{RF09} Invalid band. The RAU doesn't support programmed band. Check the
RAU type against
th
e band programmed in the hub.
{RF10} Low input DC voltage. Check the coaxial cable for high RF loss. Try
another Hub
port. If the fault persists, replace the RAU. If the fault clears,
mark the Hub port as unusable and replace the Hub when
possible.
{RF11} Hardware Failure (DL PLL Band 1). Cycle power once. If the fault persists, replace the RAU.
{RF12} Hardware Failure (DL PLL Band 2). Cycle power once. If the fault persists, replace the RAU.
{RF13} Hardware Failure (DL PLL Band 3). Cycle power once. If the fault persists, replace the RAU.
{RF14} Hardware Failure (UL PLL Band 1). Cycle power once. If the fault persists, replace the RAU.
{RF15} Hardware Failure (UL PLL Band 2). Cycle power once. If the fault persists, replace the RAU.
{RF16} Hardware Failure (UL PLL Band 3). Cycle power once. If the fault persists, replace the RAU.
{RF17} Hardware Failure (PA Band 1). Cycle power once. If the fault persists, replace the RAU.
{RF18} Hardware Failure (PA Band 2). Cycle power once. If the fault persists, replace the RAU.
{RF19} Hardware Failure (PA Band 3). Cycle power once. If the fault persists, replace the RAU.
{RF20} Hardware Failure (UL Pilot). Cycle power once. If the fault persists, replace the RAU.
{RL21} Commanded Out-of-service (Band 1). Band 1 commanded out-of-service by User.
Command
In-Service
on Band 1 to restore service.
{RL22} Commanded Out-of-service (Band 2). Band 2 commanded out-of-service by User. Command
In-Service
on Band 2 to restore service.
{RL23} Commanded Out-of-service (Band 3). Band 3 commanded out-of-service by User.
Command
In-Service
on Band 3 to restore service.
{RF24} Problem detected in the RAU. Contact TE Support for more information.
{RX25} Commanded shutdown (Band 1). Check the status of hub to which
the RAU is connected.
{RX26} Commanded sh
utdown (Band 2). Check the status of hub to which the RAU is connected.
{RX27} Commanded sh
utdown (Band 3). Check the status of the hub to which the RAU is connected.
{RF28} Internal shutdown (Band 1). RAU Fault condition in band 1
path (or common path).
{RF29} Internal shutdown (Band 2). RAU Fault
condition in band 2 path (or common path).
{RF30} Internal shutdown (Band 3). RAU Fault
condition in band 3 path (or common path).
{RF31} P
roblem detected in the system. Contact TE Support for more information.
{RF32} Problem detected in the RAU. Contact TE Support for more information.