Connecting Contact Alarms to a Fusion Wideband System
InterReach Fusion Wideband Installation, Operation, and Reference Manual Page 157
D-620616-0-20 Rev K TECP-77-044 Issue 9 March 2015 © 2015 TE Connectivity
Alarm Source
Fusion Wideband always acts as an alarm source, no matter what type of equipment is connected
to it. Refer to Alarm Sense” on page 160 if you want Fusion Wideband to sense Unison contact
closures or other external alarms.
NOTE: The following procedures assume that the system is installed and has been programmed with
bands.
Using FlexWave Focus to Monitor Fusion Wideband
When you connect FlexWave Focus to the Fusion Wideband, the Fusion Wideband Main Hub is
the output of the alarms (alarm source) and Focus is the input (alarm sense), as shown in
Figure 27.
NOTE: Focus supports only faults (major errors).
Figure 27. Connecting FlexWave to Fusion Wideband
Band 1 Band 2 Band 3
UL1 UL2 UL3
Alarms
DL1 DL2 DL3
AC Power
Band 1 Band 2 Band 3
UL1 UL2 UL3
Alarms
DL1 DL2 DL3
AC Power
Fusion Main Hub
May need
9-pin Adapter
that ships
with the cable
Alarm
Sense
5-port Alarm Daisy-Chain Cable
Alarm
Source
Alarm
Source