Installing a Fusion Wideband Main Hub
InterReach Fusion Wideband Installation, Operation, and Reference Manual Page 115
D-620616-0-20 Rev K TECP-77-044 Issue 9 March 2015 © 2015 TE Connectivity
INSTALLING A FUSION WIDEBAND MAIN HUB
CAUTION! Install Fusion Wideband Main Hubs in indoor locations only.
NOTE: The following procedure assumes that the system is new from the factory and that it has not
been programmed with bands. If you
are replacing components in a pre-installed system with
either new units or units that may already be programmed (for example, re-using units from
another system), refer to “Replacing Fusion Wideband Components” on page 175.
Installing a Fusion Wideband Main Hub in a Rack
The Fusion Wideband Main Hub (2U high) mounts in a standard 19 in. (483 mm) equipment rack.
Allow clearance of 76 mm (3 in.) front and rear, and 51 mm (2 in.) on both sides for air circulation.
No top or bottom clearance is required. Figure 17 shows the mounting bracket that secures the
Hub to the equipment rack.
Figure 17.
Mounting Bracket Detail
Do the following to install the Hub in a rack:
1 Confirm that
the mounting screws match the rack’s threads. (The Fusion Wideband Main Hub
ships with #10-32 mounting screws; another common rack thread is #12-24.)
2 Insert spring nuts into rack where
needed or use existing threaded holes.
3 Insert the Hub into
the rack from the front.
4 Align the flange holes with the s
pring nuts installed in Step 2.
5 Insert the mo
unting screws in the appropriate positions in the rack.
6 Tighten th
e mounting screws.