SAFETY PRECAUTIONS
Installation Guidelines
Use the following guidelines when installing TE equipment:
1 Provide sufficient airflow and cooling to the eq
uipment to prevent heat build-up from
exceeding the maximum ambient air temperature specification. Do not compromise the
amount of airflow required for safe operation of the equipment.
2 If you are removing the system, turn it off and remove the power cord first. There are no
user-se
rviceable parts inside the components.
3 The internal power supplies have internal fuses that are not user replaceable
. Consider the
worst-case power consumption shown on the product labels when provisioning the
equipment’s AC power source and distribution.
4 Verify t
hat the Hub is grounded prope
rly using the AC power cord third wire ground.
CAUTION! Be careful with the mechanical loading of the rack mounted hub. Mount the equipment in the
rack in such a way that a hazardous condition, due to uneven mechanical loading, does not
result.
General Safety Precautions
The following precautions apply to TE products:
The units have no user-serviceable parts. F
aulty or failed units are fully replaceable through
TE, see Appendix D: Contacting TE Connectivity” on page 229.
Wh
en you connect the fiber optic cable, clean all optical fiber
SC/APC connectors according to
the cable manufacturer’s instructions.
When you connect a radiating antenna to a RAU, firmly hand-tighten the N connector.
DO NOT o
ver-tighten the connector.
CAUTION! To reduce the risk of fire or electric shock, do not expose this equipment to rain or moisture. The
components are intended for indoor use only. Do not install the RAU outdoors. Do not connect
a RAU to an antenna that is located outdoors where it could be subject to lightning strikes, power
crosses, or wind.
The Expansion Hub and RAU units are designed for intra-building cabling only. Outdoor
routing of any cabling to these units shall not exceed 140 feet.
CAUTION! Outdoor cables farther than 140 feet must be installed with proper lightning protection.