User Manual
Help Hot Line (U.S. only): 1-800-530-9960 2-19
D-620616-0-20 Rev G CONFIDENTIAL
System Specifications
2500/2500 RAU
Table 2-22
Typical
Parameter Downlink Uplink
Average gain with 130 m RG-59 at 25°C (77°F) (dB)
15 15
Ripple with 130 m RG-59 (dB)
4.5 4.5
Output IP3 (dBm)
42.5
Input IP3 (dBm)
–5
Output 1 dB Compression Point (dBm)
32
Noise Figure 1 MH, 1 EH, 8 RAUs (dB)
17
Noise Figure 1 MH, 4 EH, 32 RAUs (dB)
23
2500 MHz RF End-to-End Performance
2600/2600 RAU
Table 2-23
Typical
Parameter Downlink Uplink
Average gain with 130 m RG-59 at 25°C (77°F) (dB)
15 15
Ripple with 130 m RG-59 (dB)
4.5 5
Output IP3 (dBm)
38
Input IP3 (dBm)
–5
Output 1 dB Compression Point (dBm)
26
Noise Figure 1 MH, 1 EH, 8 RAUs (dB)
17
Noise Figure 1 MH, 4 EH, 32 RAUs (dB)
23
2600 MHz RF End-to-End Performance