User Manual

Help Hot Line (U.S. only): 1-800-530-9960 2-17
D-620616-0-20 Rev G CONFIDENTIAL
System Specifications
700 ABC/AWS HP/AWS HP RAU
Table 2-18 700 MHz (Lower ABC) RF End-to-End Performance
Typical
Parameter Downlink Uplink
Average gain with 130 m RG-59 at 25°C (77°F) (dB)
15 15
Ripple with 130 m RG-59 (dB)
2.5 3
Output IP3 (dBm)
38
Input IP3 (dBm)
–5
Output 1 dB Compression Point (dBm)
26
Noise Figure 1 MH, 1 EH, 8 RAUs (dB)
16
Noise Figure 1 MH, 4 EH, 32 RAUs (dB)
22
Table 2-19 AWS RF End-to-End Performance
Typical
Parameter Downlink Uplink
Average gain with 130 m RG-59 at 25°C (77°F) (dB)
20 15
Ripple with 130 m RG-59 (dB)
3.5 4
Output IP3 (dBm)
43
Input IP3 (dBm)
–5
Output 1 dB Compression Point (dBm)
31
Noise Figure 1 MH, 1 EH, 8 RAUs (dB)
17
Noise Figure 1 MH, 4 EH, 32 RAUs (dB)
23
700 UC/AWS HP/AWS HP RAU
Table 2-20 700 MHz (Upper C) RF End-to-End Performance
Typical
Parameter Downlink Uplink
Average gain with 130 m RG-59 at 25°C (77°F) (dB)
15 15
Ripple with 130 m RG-59 (dB)
2.5 3
Output IP3 (dBm)
38
Input IP3 (dBm)
–5
Output 1 dB Compression Point (dBm)
26
Noise Figure 1 MH, 1 EH, 8 RAUs (dB)
16
Noise Figure 1 MH, 4 EH, 32 RAUs (dB)
22