User's Manual
Table Of Contents
- SECTION 1 General Information
- SECTION 2 InterReach Fusion Wideband System Description
- SECTION 3 Fusion Wideband Main Hub
- SECTION 4 Fusion Wideband Expansion Hub
- SECTION 5 Remote Access Unit
- SECTION 6 Designing a Fusion Wideband Solution
- SECTION 7 Installing Fusion Wideband
- 7.1 Installation Requirements
- 7.2 Safety Precautions
- 7.3 Preparing for System Installation
- 7.4 Fusion Wideband Installation Procedures
- 7.5 Splicing Fiber Optic Cable
- 7.6 Interfacing the Fusion Wideband Main Hub to an RF Source
- 7.7 Connecting Contact Alarms to a Fusion Wideband System
- 7.8 Alarm Monitoring Connectivity Options
- SECTION 8 Replacing Fusion Wideband Components
- SECTION 9 Maintenance, Troubleshooting, and Technical Assistance
- APPENDIX A Cables and Connectors
- A.1 75 Ohm CATV Cable
- A.2 Fiber Optical Cables
- A.3 Coaxial Cable
- A.4 Standard Modem Cable
- A.5 TCP/IP Cross-over Cable
- A.6 DB-9 to DB-9 Null Modem Cable
- APPENDIX B Compliance
- B.1 Fusion Wideband System Approval Status
- B.2 Human Exposure to RF
- APPENDIX C Faults, Warnings, Status Tables for Fusion, Fusion Wideband, Fusion SingleStar
- C.1 Faults Reported by Main Hubs
- C.2 Faults Reported for System CPU
- C.3 Faults for Expansion Hubs
- C.4 Faults for RAUs
- C.5 Messages for Main Hubs
- C.6 Messages for System CPUs
- C.7 Messages for Expansion Hubs
- C.8 Messages for RAUs
C-4 InterReach Fusion Wideband Installation, Operation, and Reference Manual
ADC CONFIDENTIAL D-620616-0-20 Rev D
{MT148} Port 4 Cable Fault. Possible electrical short in the coax cable, or RAU
problem.
{MT149} Port 5 Cable Fault. Possible electrical short in the coax cable, or RAU
problem.
{MT150} Port 6 Cable Fault. Possible electrical short in the coax cable, or RAU
problem.
{MT151} Port 7 Cable Fault. Possible electrical short in the coax cable, or RAU
problem.
{MT152} Port 8 Cable Fault. Possible electrical short in the coax cable, or RAU
problem.
{MT153} Port 1 Trip. Remote Unit is drawing too much current.
{MT154} Port 2 Trip. Remote Unit is drawing too much current.
{MT155} Port 3 Trip. Remote Unit is drawing too much current.
{MT156} Port 4 Trip. Remote Unit is drawing too much current.
{MT157} Port 5 Trip. Remote Unit is drawing too much current.
{MT158} Port 6 Trip. Remote Unit is drawing too much current.
{MT159} Port 7 Trip. Remote Unit is drawing too much current.
{MT160} Port 8 Trip. Remote Unit is drawing too much current.
{MF161} Problem detected in the Hub. Contact ADC Support for more information.
{MF162} Problem detected in the Hub. Contact ADC Support for more information.
{MF163} Problem detected in the Hub. Contact ADC Support for more information.
{MF164} Problem detected in the Hub. Contact ADC Support for more information.
{MF165} Problem detected in the Hub. Contact ADC Support for more information.
{MF166} Problem detected in the Hub. Contact ADC Support for more information.
{MF167} Problem detected in the Hub. Contact ADC Support for more information.
{MF168} Problem detected in the Hub. Contact ADC Support for more information.
{MF169} Problem detected in the Hub. Contact ADC Support for more information.
{MF170} Problem detected in the Hub. Contact ADC Support for more information.
{MF171} Problem detected in the Hub. Contact ADC Support for more information.
{MF172} Problem detected in the Hub. Contact ADC Support for more information.
{MF173} Problem detected in the Hub. Contact ADC Support for more information.
{MF174} Problem detected in the Hub. Contact ADC Support for more information.
{MF175} Problem detected in the Hub. Contact ADC Support for more information.
{MF176} Problem detected in the Hub. Contact ADC Support for more information.
Table C-1 Fault Messages for Main Hubs (continued)
Message