A-6 InterReach Fusion Wideband Installation, Operation, and Reference Manual
CONFIDENTIAL D-620616-0-20 Rev D
* Exceeding the distance of copper-clad cable will result in the attached RAU becoming
non-functional. If the distance of a cable run is at its maximum and is of concern, ADC recom-
mends the use of solid copper cable to ensure successful operation.
A.2 Fiber Optical Cables
Connects the Main Hub to Expansion Hub(s)
Transmits (downlink) and receives (uplink) optical signals
Carries configuration and status information
Use industry-standard 62.5µm/125µm MMF or Corning SMF-28 fiber, or equiva-
lent.
SC/APC (angle-polished) connectors are required throughout the fiber network
(port-to-port), including fiber distribution panels
Table A-1 System Gain (Loss) Relative to CATV Cable Length
Cable
Type
Comm-
Scope
Part
Number
Plenum
Rated
Solid
Copper
Conductor
Copper
Clad
Conductor
Zero-loss
RF
Maximum
Length
(meters)
Distance
Where
RF is
10dB
Below
Input RF
(meters)
RG-59
2065V Yes X 130 180
2022V Yes X 100 100*
5572R No X 95 95*
5565 No X 130 180
RG-6
2279V Yes X 140 190
2275V Yes X 140 150*
5726 No X 140 140*
5765 No X 140 190
RG-11
2293K Yes X 235 320
2285K Yes X 235 300*
5913 No X 235 300*