For a PCS 1900 remote unit, the maximum power output, according to the power
table in Section 6.3 Maximum Output Power per Carrier on page 6-4, is 16.5 dB.
Assuming a 7 dBi antenna is used, PG in the equation is equal to 23.5 dB (224 mW)
EIRP.
Using S = PG/4
πR
2
S = 224/(4x3.14) x (122)
2
= 0.001 mW/cm
2
Also, assuming a minimum distance of 20 cm according to FCC regulations”
S = 224/(4 x 3.14) x (20)
2
= 0.04 mW/cm