User's Guide
Table Of Contents
- SECTION 1 General Information
- SECTION 2 InterReach Fusion System Description
- SECTION 3 Fusion Main Hub
- SECTION 4 Fusion Expansion Hub
- SECTION 5 Remote Access Unit
- SECTION 6 Designing a Fusion Solution
- SECTION 7 Installing Fusion
- SECTION 8 Replacing Fusion Components
- SECTION 9 Maintenance, Troubleshooting, and Technical Assistance
- APPENDIX A Cables and Connectors
- A.1 75 Ohm CATV Cable
- A.2 Fiber Optical Cables
- A.3 Coaxial Cable
- A.4 Standard Modem Cable
- A.5 TCP/IP Cross-over Cable
- A.6 DB-25 to DB-9 Null Modem Cable
- APPENDIX B Compliance
- B.1 Fusion System Approval Status
- B.2 Human Exposure to RF
- APPENDIX C Faults, Warnings, Status Tables
- C.1 Faults Reported by Fusion Main/SingleStar Hubs
- C.2 Faults Reported for System CPU
- C.3 Faults for Fusion Expansion Hubs
- C.4 Faults for RAUs
- C.5 Warning/Status Messages for Fusion Main/SingleStar Hubs
- C.6 Warning/Status Messages for System CPUs
- C.7 Warning/Status Messages for Fusion Expansion Hubs
- C.8 Warning /Status Messages for RAUs
Help Hot Line (U.S. only): 1-800-530-9960 2-9
D-620610-0-20 Rev B CONFIDENTIAL
System Specifications
2.6 System Specifications
Table 2-1 Physical Specifications
Parameter Main Hub Expansion Hub Remote Access Unit
IF/RF Connectors 6-type “N”, female (50 Ohm),
1 Downlink/Uplink pair per band
8-type “F”, female (CATV
75 Ohm)
One F, female (CATV -75
Ohm)
One N, female (coaxial - 50
Ohm)
External Alarm Connector
(contact source)
One, 9-pin D-sub, female One, 9-pin D-sub, female —
ADMIN/LAN Interface
Connectors
One RJ-45, female
One 9-pin D-sub, male for
optional modem
One RJ-45, female
One 9-pin D-sub, male
—
Fiber Connectors*
*It is critical to system performance that only SC/APC fiber connectors are used throughout the fiber network, including fiber distribution pan-
els.
4 pair, SC/APC One pair, SC/APC —
LED Alarm and Status
Indicators
Unit Status (One pair):
•Power
• Main Hub Status
Downstream Unit Status
(One per fiber port):
• Expansion Hub/RAU
Unit Status (One pair):
•Power
• Expansion Hub Status
Fiber Link Status (One
pair):
•DL Status
•UL Status
Port Status:
• One per F connector port
•Link/RAU
Unit Status (One pair):
•Link
•Alarm
Power (AC Option)
Power (DC Option)
Rating: 100–240V AC, 1A,
50–60 Hz
Operating Range: 90–132V
AC/170-250V AC auto-ranging
Rating: 38–64V DC, 2.5A
Rating: 100–240V AC,
6A, 50–60 Hz
Operating Range:
90–132V AC/170-250V
AC auto-ranging
—
Power Consumption (W) 30 4 RAUs: 305 typical
8 RAUs: 530 typical
—
Enclosure Dimensions†
(height
× width × depth)
†Excluding angle-brackets for 19'' rack mounting of hub.
Note: The Fusion Main Hub’s typical power consumption assumes that the CATV RG-59 cable length is no more than 150 meters, the RG-6
cable length is no more than 170 meters, and RG-11 cable length is no more than 275 meters using CommScope 2065V, 2279V, and 2293K
cables.
89 mm × 438 mm × 381 mm
(3.5 in. × 17.25 in. × 15 in.) (2U)
89 mm × 438 mm × 381
mm
(3.5 in. × 17.25 in. × 15
in.) (2U)
54 mm x 286 mm x 281 mm
(2.13 in. × 11.25 in. × 11.13
in.)
Weight < 5.5 kg (< 12 lbs.) < 6.6 kg (< 14.5 lbs.) < 2.1 kg (< 4.6 lbs.)