Table 2-2 Wavelength and Laser Power Specifications
Measured Output Power
Wavelength Main Hub Expansion Hub
1310 nm +
20 nm 890 uW 3.8 mW
Table 2-3 Environmental Specifications
Parameter Main Hub and Expansion Hub RAU
Operating Temperature 0° to +45°C (+32° to +113°F) –25° to +45°C
(–13° to
+113°F)
Non-operating Temperature –20° to +85°C (–4° to +185°F) –25° to +85°C
(–13° to
+185°F)
Operating Humidity; non-con-
densing
5% to 95% 5% to 95%
Table 2-4 Frequency Bands Covered by Fusion RAUs
Fusion
RAU Part Number
Fusion
Band
RF Passband
Downlink
(MHz)
Uplink
(MHz)
MAIN
HUB/
RAU
Band
RAU
Band-
width
850/1900 FSN-8519-1 850 869–894 824–849 1 25 MHz
1900 1930–1990 1850–1910 2 60 MHz
900/1800 FSN-9018-1 900 925–960 880–915 1 35 MHz
1800 1805–1880 1710–1785 2 75 MHz
900/2100 FSN-9021-1 900 925–960 880–915 1 35 MHz
2100 2110–2170 1920–1980 2 60 MHz
850/1800 FSN-8518-1 850 869-894 824-849 1 25 MHz
1800 1805-1880 1710-1785 2 75 MHz
850/2100 FSN-8521-1 850 869-894 824-849 1 25 MHz
2100 2110-2170 1920-1980 2 60 MHz