User's Manual Part 2
Appendix C: Faults, Warnings, Status Tables for Fusion, Fusion Wideband, Fusion SingleStar
Page 226 InterReach Fusion Wideband Installation, Operation, and Reference Manual
© 2013 TE Connectivity Ltd D-620616-0-20 Rev H • TECP-77-044 Issue 7 • May 2013
MESSAGESFORRAUS
ͳͲͷǡǣ
[Rnn]/X
• nn
• X
– S—
– W—Ǥ
Table105. Warning/StatusMessagesforRAUs
Message
Number
Default
Description Reason/Action
[R01]/W Temperature High. Check RAU location for excessive temperature; check for air flow
blockage and/or incorrect installation. Move the RAU to a cooler
environment.
[R02]/W No communications from Hub. Check the cable for high RF loss. Switch the cable connection to a
different hub port. If the problem persists, replace the RAU.
[R03]/W DL RF path loss is too high. Check the cable for high RF loss. Switch the cable connection to a
different hub port. If the problem persists, replace the RAU.
[R04]/W DL RF path exceeds maximum gain. Check the Hub for proper operation; switch the cable connection
to a different hub port. If the problem persists, replace the RAU.
[R05]/S DL RF path problem (Band 1). Unable to complete the DL system end-to-end test, replace the
RAU when possible.
[R06]/S DL RF path problem (Band 2). Unable to complete the DL system end-to-end test, replace the
RAU when possible.
[R07]/S DL RF path problem (Band 3). Unable to complete the DL system end-to-end test, replace the
RAU when possible.
[R08]/S System test required. Run system test.
[R09]/W Antenna Disconnected. Check RAU antenna connection; re-run system test.
[R10]/S UL RF path problem (Band 1). Unable to complete the UL system end-to-end test, replace the
RAU when possible.
[R11]/S UL RF path problem (Band 2). Unable to complete the UL system end-to-end test, replace the
RAU when possible.
[R12]/S UL RF path problem (Band 3). Unable to complete the UL system end-to-end test, replace the
RAU when possible.
[R13]/S Problem detected in the RAU. Contact TE Support for more information.
[R14]/S Problem detected in the RAU. Contact TE Support for more information.
[R15]/S Problem detected in the RAU. Contact TE Support for more information.
[R16]/S Problem detected in the RAU. Contact TE Support for more information.
[R17]/S Antenna disconnected (Band 1). Check the RAU Band 1 antenna, then rerun the system test.
[R18]/S Antenna disconnected (Band 2). Check the RAU Band 2 antenna, then rerun the system test.
[R19]/S Hardware Failure (UL FD PLL Band 1). Unable to complete a UL system end-to-end test. Replace the RAU
when possible.