User's Manual Part 1
Remote Access Unit
Page 60 InterReach Fusion Wideband Installation, Operation, and Reference Manual
© 2013 TE Connectivity Ltd D-620616-0-20 Rev H • TECP-77-044 Issue 7 • May 2013
REMOTEACCESSUNITSPECIFICATIONS
NOTE: Forsystemperformance,itisimportantthatyouuseonlylowloss,solidcoppercenterconductor
CATVcablewithqualityFconnectorsthatusecaptivecenterpinconductors.Referto“Appendix
A:CablesandConnectors”onpage191formoreinformation.
Table39. RemoteAccessUnitSpecifications
Specification Description
Dimensions (H u W u D) 54 mm × 286 mm × 281 mm
(2.13 in. × 11.25 in. × 11.13 in.)
Weight < 2.1 kg (< 4.6 lb.)
Operating Temperature –25° to +45°C (–13° to +113°F)
Non-operating Temperature –25° to +85°C (–13° to +185°F)
Operating Humidity, non-condensing 5% to 95%
RF Connectors One Type-F, female (CATV - 75 ohms)
One Type-N, female* (coaxial 50 ohms)
LED Alarm and Status Indicators Unit Status (1 pair):
• Link
• Alarm
Maximum Heat Dissipation (W) 50 typical, 64 max (from the Hub)
MTBF 202,684 hours
* Two type N female connectors for FSN-W1-1921-1, FSN-W2-808519-1, FSN-W2-7070-1,
FSN-W2-7575-1, FSN-W3-2626-1, FSN-W4-702121-1-HP, FSN-W4-752121-1-HP,
FSN-W5-851921-1-HP, and FSN-2500-2-WMAX RAUs