User's Manual Part 1

Installing Fusion Wideband
Page 108 InterReach Fusion Wideband Installation, Operation, and Reference Manual
© 2013 TE Connectivity Ltd D-620616-0-20 Rev H TECP-77-044 Issue 7 May 2013

ǡǤ
ǣ
ǦͶʹͲ͸ͷ
Ǧͷͷʹʹ͹ͻ
Ǧ͹ͳʹʹͻ͵
CAUTION! Thepropercrimptoolanddiemustbematchedbytheconnectortype.
DistanceRequirements
ͺ͵Ǥ
Table83. DistanceRequirements
Equipment
Combination
Cable Type Cable Length Additional Information
Repeater/BTS to
Fusion Wideband
Main Hub
Coaxial; N male
connectors
3–6 m (10–20 ft) typical Limited by loss and noise.
Refer to your link budget
calculation.
10 m (33 ft) maximum Limited by CE Mark
requirements.
Fusion Wideband
Expansion Hub to
RAU
CATV 75 Ohm;
shielded F male
connectors
Minimum: 10 meters (33 ft)
Maximum:
150 meters (492 ft) for RG-59;
170 meters (558 ft) for RG-6;
275 meters (902 ft) for RG-11
Refer to Table 37 on page 55 and Table 38 on
page 56.
Refer to “System Gain” on
page 81.
Main Hub to
Expansion Hub
Multi-mode fiber:
Single-mode fiber:
SC/APC male
connectors
500 m (1640 ft.) maximum
6 km (19,685 ft.) maximum
Limited by 3 dB optical
attenuation
RAU to passive
antenna
Coaxial; N male
connectors
1–3.5 m (3–12 ft) typical Limited by loss and noise.
Refer to your link budget
calculation.