User's Manual
Faults and Warnings
5-8 InterReach Fusion Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620610-0-20 Rev G
5.4 Faults and Warnings
Both fault and warning conditions are reported to the Fusion Hub where they are
stored. Only faults are indicated by the faceplate LEDs.
For more information, refer to Appendix C.
5.5 Remote Access Unit Specifications
Table 5-5 Remote Access Unit Specifications
Specification Description
Dimensions (H
u W u D)
54 mm × 286 mm × 281 mm
(2.13 in. × 11.25 in. × 11.13 in.)
Weight < 2.1 kg (< 4.6 lb.)
Operating Temperature –25° to +45°C (–13° to +113°F)
Non-operating Temperature –25° to +85°C (–13° to +185°F)
Operating Humidity, non-condensing 5% to 95%
RF Connectors One Type-F, female (CATV - 75 ohms)
One Type-N, female
a
a. Two type N female connectors for FSN-2-708519-1, FSN-2-758519-1, FSN-2-708519-1-HP and
FSN-2-758519-1-HP RAUs
(antenna 50 ohms)
LED Alarm and Status Indicators Unit Status (1 pair):
• Link
• Alarm
Maximum Heat Dissipation (W) 50 typical, 64 max (from the Hub)
MTBF 211,600 hours (All Dual Band RAUs)
144,409 hours (800/900/1900 Tri-Band RAUs)
NOTE: For system performance, it is important that you use only low loss,
solid copper center conductor CATV cable with quality F connectors that use
captive centerpin conductors. Refer to Appendix A for more information.