User's Manual

Table Of Contents
RAU Overview
5-4 InterReach Fusion Wideband Installation, Operation, and Reference Manual
CONFIDENTIAL D-620616-0-20 Rev C
* Exceeding the distance of copper-clad cable will result in the attached RAU becoming
non-functional. If the distance of a cable run is at its maximum and is of concern, ADC recom-
mends the use of solid copper cable to ensure successful operation.
Table 5-2 System Gain (Loss) Relative to CATV Cable Length
Cable
Type
Comm-
Scope
Part
Number
Plenum
Rated
Solid
Copper
Conductor
Copper
Clad
Conductor
Zero-loss
RF
Maximum
Length
(meters)
Distance
RF is
10dB
Below
Input RF
(meters)
RG-59
2065V Yes X 130 180
2022V Yes X 100 100*
5572R No X 95 95*
5565 No X 130 180
RG-6
2279V Yes X 140 190
2275V Yes X 140 150*
5726 No X 140 140*
5765 No X 140 190
RG-11
2293K Yes X 235 320
2285K Yes X 235 300*
5913 No X 235 300*