User's Manual Part 2

Table Of Contents
Appendix A: Cables and Connectors
Page 196 InterReach Fusion Wideband Installation, Operation, and Reference Manual
© 2013 TE Connectivity Ltd D-620616-0-20 Rev H TECP-77-044 Issue 7 May 2013
ConnectorsandToolsforCableEnds
Usethefollowingconnectorsandtoolstopreparethecableends:
CommSc
opecablepartnumber:2065V
Canarepartn
umber:FconnectorFP‐C4F
CrimpToolTC‐1
,CrimpDieTCD‐4C,CableStrippreparationtoolTS100E
CommSc
opecablepartnumber:2279V
Canarepartn
umber:FconnectorFP‐C55A
CrimpToolTC‐1
,CrimpDieTCD‐35CA,CableStrippreparationtoolTS100E
CommSc
opecablepartnumber:2293V
Canarepartn
umber:FconnectorFP‐C71A
CrimpToolTC‐1
,CrimpDieTCD‐7CA,CableStrippreparationtoolTS100E
Ifthemaximumdistanceisnotrequired,thencoppercladoversteel‐ce
nterconductorcablemay
beusedtoreducecablecosts.
Table96showCommScopecablechoicesofple
num,non‐plenum,solidcopperconductor,and
copper‐cladover‐steelconductorca
blewiththeirpartnumbersandmaximumdistances.
Table96.
SystemGain(Loss)RelativetoCATVCableLength
Cable
Type
CommScope
Part Number
Plenum
Rated
Solid Copper
Conductor
Copper Clad
Conductor
Zero-loss RF
Maximum
Length
(meters)
Distance
Where RF
is 10dB
Below Input
RF
(meters)
RG-59
2065V Yes X 130 180
2022V Yes X 100 100*
5572R No X 95 95*
5565 No X 130 180
RG-6
2279V Yes X 140 190
2275V Yes X 140 150*
5726 No X 140 140*
5765 No X 140 190
RG-11
2293K Yes X 235 320
2285K Yes X 235 300*
5913 No X 235 300*
* Exceeding the distance of copper-clad cable will result in the
attached RAU becoming non-functional.
If the distance of a cable run is at its maximum and is of concern, TE recommends the use of solid
copper cable to ensure successful operation.