75OHMCATVCABLE
GeneralSpecifications
• ConnectstheExpansionHubtotheRAU(s)
• Transmitsmultiband(downlink
)andreceives(uplink)IFsignals
• Delive
rsDCelectricalpowertotheRAUs.TheFusionHub’sDCvoltageoutputis54VDC
nominal.AcurrentlimitingcircuitisusedtoprotecttheHubifitreachesitscurrentlimit
• Carriesconfigurationandstatusinformatio
n
• Use75Ohmtype‐F
connectorswithcaptivecenterpins
• Le
ngths
– RG
‐59:
•Minimum:0meters(0ft.)
•Maximum:150meters(492ft.)
– RG
‐6:
•Minimum:0meters(0ft.)
•Maximum:170meters(558ft.)
– RG
‐11:
•Minimum:0meters(0ft.)
•Maximum:275meters(902ft.)
RecommendedCATVCableLengths
RecommendedminimumandmaximumCATVcablelengthsvarydependinguponwhichCATV
cableyouuse.(Besuretotestcableterminationbeforeinstallingthecable.)
• CommScopeCATVcableorequivale
ntisrequired:
• Comm
Scope20655VforRG‐59.ThiscableisillustratedinFigureA‐1.
• Comm
Scope2279VforRG‐6.ThiscableisillustratedinFigureA‐2.
• Comm
Scope2293KforRG‐11.ThiscableisillustratedinFigureA‐3.
• Comm
Scope2065VforRG‐59
• Comm
Scope2279VforRG‐6
• Comm
Scope2293KforRG‐11