User's Manual Part 2

Table Of Contents
Maintenance, Troubleshooting, and Technical Assistance
Page 184 InterReach Fusion Wideband Installation, Operation, and Reference Manual
© 2013 TE Connectivity Ltd D-620616-0-20 Rev H TECP-77-044 Issue 7 May 2013
TROUBLESHOOTING
NOTE: Fusionhasnous erserviceableparts.FaultyorfailedunitsarefullyreplaceablethroughTE;see
“Service”onpa
ge182.
Sourcesofpotentialproblemsinclude:
Faultycablin
g/connector
Malfunctio
nofoneormoreFusioncomponents
Antenna,bases
tation,orrepeaterproblem
Ext
ernalRFinterface
Trippedcircuitbreaker
Equipmentisnotgrounded
UsinganEthernetcrossovercab
lethatdoesnotsupportfullhardwarehandshakingwhen
usingAdminBrowser
NOTE: Faultycablingisthecauseofavastmajorityofpro blems.AllCATV75Ohmcableshouldbetested
to TIA570B specifications. The RAU will be damaged if the cable connector is not installed
properly.
YoumustuseAdminBrowserfortroubleshootingthesystem,usetheLEDsonlyasbackuporfor
confirmation.
Ifyoucannotdeterminethecause
ofaproblemafterfollowingtherecommendedprocedures,call
theTECustomerSupportTeam.Forinformationonhowtocontactus,see“Service”onpa
ge182.
Pleaseprovidethefollo
winginformation:
Serialnum
beroftheunit
Descrip
tionoftheproblem
Us
eAdminBrowser1.00toaccessSpecialFeatures,thentheGetServiceInformationwindow.
SaveandemailthisfiletoTE.
Wh
atisthelengthoftheCATVcable?Whattypeisit(forexampleRG‐6)?
StatusoftheL
EDsontheunit
Wastheunitpowercycled?