User's Manual Part 2
Table Of Contents
- Replacing Fusion Wideband Components
- Maintenance, Troubleshooting, and Technical Assistance
- Appendix A: Cables and Connectors
- Appendix B: Compliance
- Appendix C: Faults, Warnings, Status Tables for Fusion, Fusion Wideband, Fusion SingleStar
- Appendix D: Contacting TE Connectivity
Installing Fusion Wideband
Page 110 InterReach Fusion Wideband Installation, Operation, and Reference Manual
© 2013 TE Connectivity Ltd D-620616-0-20 Rev H • TECP-77-044 Issue 7 • May 2013
FiberPortSafetyPrecautions
Thefollowingaresuggestedsafetyprecautionsforworkingwithfiberports.Forinformation
aboutsystemcompliancewithsafetystandards,referto“AppendixB:Compliance”onpage203.
CAUTION! Observethefollowingwarningaboutviewingfiberendsinports.Donotstarewithunprotected
eyesattheconnectorendsofthefibersortheportsofthehubs.Invisibleinfraredradiationis
presentatthefrontpaneloftheMainHubandtheExpansionHub.Donotremovethefiberpo
rt
dustcapsunlesstheportisgoingtobeused.Donotstaredirectlyintoafiberport.
• Testfibercables:Whenyoutestfiberopticcables,connecttheopticalpowersourcelastand
disconnectitfirst.UseClass1testequipment.
• Fiberen
ds:Coveranyunconnectedfiberendswithanapprovedcap.Donotusetape.
• Bro
kenfibercables:Donotstarewithunprotectedeyesatanybrokenendsofthefibers.
Laserlightemittedfromfibersourcescancauseeyeinjury.Avoidcontactwithbrokenfibers;
theyaresharpandcanpiercetheskin.Reportanybrokenfibercablesandhavethem
replaced.
• Cl
eaning:Besuretheconnectorsarecleanandfreeofdustoroils.Useonlyapproved
methodsforcleaningopticalfiberconnectors.
• Modifications:D
onotmakeanyunauthorizedmodificationstothisfiberopticsystemor
associatedequipment.
• Livework:Liveworkis
permittedbecauseTEequipmentisaClass1hazard.
• Signs:N
owarningsignsarerequired.
• Class1laserprod
uct:ThesystemmeetsthecriteriaforaClass1laserproductperIEC
60825‐1:1993+A1:+A2:2001andIEC106825‐2.
Complieswith21CFR1040.10and
1040.11exceptfordeviationspursuanttoLaserNotice
No.50,datedJuly26,2001.
Thehazardlevelatalllocationswithinthe
equipmentisHazardLevel1.
CAUTION! Useofcontrolsoradjustmentsorperformanceofproceduresotherthanthosespecifiedherein
mayresultinhazardousradiationexposure.