Installing Fusion Wideband
Page 150 InterReach Fusion Wideband Installation, Operation, and Reference Manual
© 2013 TE Connectivity Ltd D-620616-0-20 Rev H • TECP-77-044 Issue 7 • May 2013
CAUTION! OnlyTEperson nelorTE‐authorizedinstallationpersonnelshouldconnecttheFusionWideband
MainHubtoabasestationorrepeater.Exceedingthemaximuminputpowercouldcausefailure
of the Fusion Wideband Main Hub (refer to “RemoteAcce
ss Unit Connectors” on page57 for
maximum po
werspecifications). Ifthe maximum composite poweris too high, attenuation is
required.
Youcanusepowercombiner/splitterstoconnectaFusionWidebandMainHubRFBandto
multiplebasestations,asshowninFigure42onpage150.
Figure42
.Connecting a Fusion Wideband Main Hub to Multiple Base Stations
ConnectingaFusionWidebandMainHubRFBandtoMultipleBTSs
Band 1 Band 2 Band 3
UL1 UL2 UL3
Alarms
DL1 DL2 DL3
AC Power
Insert attenuators
(if needed)
2 x 1 Power
Combiner/Splitter
N-male to N-male
coaxial-jumper cables
between Combiner/Splitter and
Fusion Main Hub’s Uplink Port
for each on Band 1, Band 2, or Band 3
2 x 1 Power
Combiner/Splitter
N-male to N-male
coaxial-jumper cables
between Combiner/Splitter and
Fusion Main Hub’s Downlink Port
for either Band 1, Band 2, or Band 3
BTS 1
UL DL
BTS 2
UL DL