Installing Fusion Wideband
Page 148 InterReach Fusion Wideband Installation, Operation, and Reference Manual
© 2013 TE Connectivity Ltd D-620616-0-20 Rev H TECP-77-044 Issue 7 May 2013
ConnectingaSimplexBaseStationtoaFusionWidebandMainHubRFBand
1 ConnectanN‐maletoN‐malecoaxialcabletothetransmitsimplexconnectoronthebase
station.
2 Connect
theotherendoftheN‐maletoN‐malecoaxialcabletotheDOWNLINKconnectoronthe
HubforthecorrespondingBand1,Band2,orBand3.
3 ConnectanN‐maletoN‐malecoaxialcableto
thereceivesimplexconnectoronthebase
station.
4 Connecttheo
therendoftheN‐maletoN‐malecoaxialcabletotheUPLINKconnectoronthe
HubforthecorrespondingBand1,Band2,orBand3.
Figure40.
Simplex Base Station to a Fusion Wideband Main Hub
Simplex
Base Station
Band 3
Band 1 Band 2 Band 3
UL1 UL2 UL3
Alarms
DL1 DL2 DL3
AC Power
N-male to N-male
coaxial cable
T1/E1 to
Mobile
Switching
Center
Insert attenuator
(if needed)
NOTE: This applies to Band 1, Band 2, and Band 3.