Interfacing the Fusion Wideband Main Hub to an RF Source
InterReach Fusion Wideband Installation, Operation, and Reference Manual Page 147
D-620616-0-20 Rev H • TECP-77-044 Issue 7 • May 2013 © 2013 TE Connectivity Ltd.
INTERFACINGTHEFUSIONWIDEBANDMAINHUBTOANRFSOURCE
CAUTION! OnlyTEperson nelorTE‐authorizedinstallationpersonnelshouldconnecttheFusionWideband
MainHubtoitsBandassociatedbasestationorrepeater.Exceedingthemaximuminputpower
couldcausefailureoftheFusionWidebandMainHub(referto“RemoteAcc
essUnitConnectors”
onpa
ge57 formaximumpowerspecifications).If themaximum compositepoweris toohigh,
attenuationisreq
uired.
NOTE: Thefollowing pr
oceduresassume thatthesystemisinstalledandhasbeenprogrammed with
bands.
ConnectingaSingleFusionWidebandMainHubtoanRFSource
TheFusionWidebandsystemsupportsthreeRFsources,oneforBand1,Band2,andBand3.This
sectionexplainshoweachBandcanbeconnectedtoitsassociatedRFsource.
CAUTION! OnlyTEperson nelorTE‐authorizedinstallationpersonnelshouldconnecttheFusionWideband
MainHubtoabasestationorrepeater. Exceedingthe maximuminputpowercouldcausefailure
of the Fusion WidebandMain Hub (refer to “RemoteAcce
ss Unit Connectors” on page57 for
maximum po
werspecifications). Ifthe maximum composite poweris too high, attenuation is
required.
CAUTION! The
UPLINKand DOWNLINK portscannot handlea DC power feedfromthebasestation.If DC
powerispresent,aDCblockmustbeusedorthehubmaybedamaged.
ConnectingaFusionWidebandMainHubtoanIn‐BuildingBTS