Page 136 InterReach Fusion Wideband Installation, Operation, and Reference Manual
© 2013 TE Connectivity Ltd D-620616-0-20 Rev H TECP-77-044 Issue 7 May 2013
1 Verifythatthecablehasbeentestedandthetestresultsarerecorded.Thisinformationis
requiredfortheAs‐BuiltDocument.
2 Verifyth
atonlycaptivecenterpin75OhmType‐Fconnectorsareusedonthesolidcopper
centerconductorCATV75Ohmcable.
3 Verifyt
hattheCATVcableislabeledwith:
FusionWidebandMainHu
bportnumberbeingused
RAU
identifier
Carrier(formultipl
eoperatorsystems)
4 ConnecttheCA
TVcablestotheFfemaleportontheRAUaccordingtothelabelonthecable.
PowerissuppliedbytheFusionWidebandMainHub
overtheCATVcableconductors.Upon
powerup,theLEDswillblinkfortwosecondsasavisualcheckthattheyarefunctioning.After
thetwo‐secondtest:
The
LINKLEDshouldbegreenindicatingitisreceivingpowerandcommunicationsfrom
theFusionWidebandMainHub.
The
ALARMLEDshouldbereduntiltheFusionWidebandMainHubissuestheband
command,withinabout20seconds,thenitshouldbegreen.
5 Record
whichcableyouareconnectingtotheRAU(fromthelabelonthecable);this
informationisrequiredfortheAs‐BuiltDocument.
6 Tie‐o
ffcablesorusetheoptionalcablemanagertoavoiddamagingtheconnectorsbecauseof
cablestrain.
ConnectingtheCATVCable